8 Analog Input ,8 0-10v Analog Output Modules 11 Isolated Digital Input Modules, Modbus Tcpip,Ether

SHJ Electronic Co.,Ltd

S6135 is a high quality and low cost analog data acquisition module with 8universal analog inputs. Each input can be 0-5V,0-10V,0-20mA,thermistor,drycontact, open-collector input,8 channels 0-10V analo...

EV Charging Infrastructure SHJ Electronic Co.,Ltd 24 Dec 2025 ( )

Get Your Quote Now : US$ 139/ Piece

S6135 is a high quality and low cost analog data acquisition module with 8universal analog inputs. Each input can be 0-5V,0-10V,0-20mA,thermistor,drycontact, open-collector input,8 channels 0-10V analog output,11 isolateddigital input. The digital input can be dry contact, wet contact andopen-collector, each input also can be 32-bit counter.S6135 has RS485 and rj45two type interface,rs485 support standard Modbus RTU protocol and RJ45 supportModbus Tcpip protocol.It can easy integrate with PLC and labview with standardModbus/Modbus Tcpip protocol Highlights:l Surge-protected analog inputs with12-bit resolution and 100k sample speedl Input can be any combination of0-5V,4-20mA,0-10V,NTC 10K thermistor, open-collector and dry contactl The channel number isconfigurable, can be set up from 1 channel through 8 channels, for analog inputand set up from 1 to 11 for digital input, improve sample rate for small countinputl 8 channels 0-10V analog outputwith high accurate reference chipl Isolated digital inputs can beconfigured as counter input, total 32 bits,1000Hzl Standard ModBus TCPIPprotocol,easy work with PLCl Standard ModBus protocol allowsfor up to 254 unique devices on one RS485 networkl A lot of spare FLASH can be usedto store user’s parametersl Can update your firmware via ISPthrough RS485 network, can provide any hex file to help you finish some logiccontroll DIN support available  Application:

ü  Remote data acquisition

ü  Process monitoring

ü  Industrial process control

ü  Energy management

ü  Supervisory control

ü  Security systems

ü  Laboratory automation

ü  Building automation

ü  Product testing

ü  Direct digital control

Technicaldata:

Analog Input Resolution--------------------------------------------------------------------------------12-bitAnalog Input ChannelNumber------------------------------------------------------------------------------8

Analog Inputrange----------------------0-5V,0-10v,0-20mA, thermistor, dry contact,open-collector

Analog Input Protection---------------------------------------------------------------------Lightning,static

Analog Input Accuracy---------------------------------------------------------------------------------±0.1%

Analog Input  Zero drift-----------------------------------------------------------------------------±3uV/℃      

AnalogInput Sample Rate-----------60 sample/second(8 channels),900 sample/second(1channel) Analog OutputResolution-----------------------------------------------------------------------------12-bit

Analog Output Channel Number--------------------------------------------------------------------------8

Analog Output Range----------------------------------------------------------------------------------0-10V

Analog Output Accuracy--------------------------------------------------------------------±0.2% of FSR

Analog Output Zero Drift------------------------------------------------------------------------±30uV/℃ 

Digital Input Channel Number-----------------------------------------------------------------------------11

Digital Input Range-------------------------------------------------------------------------------+4V~+36V

Digital Input Signal----------------------------------------------wetcontact, dry contact, open-collector

Digital Input Counter Frequency------------------------------50Hz@11channels;500Hz@1channel

Digital Input Counter Length---------------------------------------------------------------------------32-bit       

OutputBUS----------------------------------------------------------------------------------Ethernet/RS485        RS232/RS485 protocol--------------------------------------------------------------MODBUS/RTU        

Ethernetprotocol------------------------------------------------------------------MODBUS/TCPIP      

OutputProtection-----------------------------------------------------------------------------Lightning,static

Powerinput---------------------------------------------------------------------------------15~24V(AC/DC)       

Powerconsumption------------------------------------------------------------------------------------<0.6WAmbienttemperature:             

Operation---------------------------------------------------------------------------20~85℃(-4~185℉)                  Storage-----------------------------------------------------------------------------------------40~125℃(-40~257℉)

Ambienthumidity-----------------------------------------------------------------------------------------------10%~90%RHMaterial,enclosure-----------------------------------------------------------------------Flameproof plastic

Enclosurerating--------------------------------------------------------------------------------------------IP31

Colour----------------------------------------------------------------------------------------------White/Black

Size---------------------------------------------------------------------------------------------115*90*43 mm

Accept AC and DC input-        : Power supply negative input

RS485 Port        B: Connect to B of RS485        A: Connect to A of RS485        R: Connect to GND for RS485Ethernet port               Connect to local Ethernet network throughRJ45 cable Inputs      

Analog:A1 ~ A8: Analog input 1 through 8

AGND: common for analog input 1 through 8,also use for analog output      

Digital:

DVCC: Power source input for digital input 1 through 3,wet contactinput available

D1 ~ D11: Digital input channel 1 through113

DGND: common for digital input 1 through 11, available in dry inputmode

Outputs      

Analog:AO1 ~ AO8: Analog output 1 through 8

AGND: common for analog output 1 through 8,also use for analog input  

LedsBEAT: Will flash when system is working

Comm: Will flashwhen RS485 serial port communication

Clients Reviews