Tuesday, 6 Oct 2026
Get Your Quote Now : US$ 200 ~ 600/ Box
SE40 Grating system
- SE40 series gratings are compact gratings for high dynamic and high precision systems. The application of single-field scanning and low-latency subdivision processing make them have high dynamic performance. Used in applications that are demanding on performance and cost at the same time, in pursuit of performance and product cost, an effective balance has been achieved.
- The SE40 series readhead is adapted to the L4 series ultra-thin stainless steel scale with a 40μm grating pitch. The expansion coefficient is exactly the same as that of the substrate, and its excellent corrosion resistance and scratch resistance make it suitable for harsh environments. The surface of the L4 scale is very Tough, so it doesn't need any protective coating to prevent the grid lines from being damaged. When the scale is contaminated, alcohol can be used to clean it, and non-polar organic solvents such as acetone and toluene can be used instead of alcohol, and the performance of the scale after cleaning will not be affected in any way.
Primary advantages
- Small and compact readhead (32×12×10.6mm).
- Single field scanning, low subdivision error.
- The magnetic zero point can be set arbitrarily, which is flexible and convenient.
- Ultra-light 7g readhead, ultra-flexible 3.4mm diameter cable, small inertia, does not affect system performance.
- Automatic gain control to ensure effective signal strength and long-termreliability.
- The reading head has 2 indicator lights visible in two directions, which is convenient for observing the signal status.
- Read head with optical coating, high signal-to-noise ratio.
- The surface of the scale is hard without coating and has strong scratch resistance.
- Scale with a thickness of 0.1mm has the same expansion coefficient as the substrate.
- 40μm small grid pitch, better running effect than magnetic grid, low noise and stable speed.
- Maximum speed 4.5m/s.
- 10μm/m scale absolute accuracy
Readhead specification
| Dimensions: | L 32mm × W 12mm × H 10.6mm |
| Grating sensor: | 40μm |
| Weight: | Reading head 7.1g,Cable 18g/m |
| Power supply: | 5V±10% 230mA, A, B, Z signal with 120ohm load |
| Output signal: | differential TTL, origin signal (optional) |
| Connector: | D-sub 15 Pin Male,D-sub 9 Pin Male |
| Resolution: | 1μm, 0.5μm |
| Electronic subdivision error: | <150nm |
| Maximum speed: | 4.5m/s |
| Reference origin (optional): | Magnetic sensor on the side of the readhead |
| Maximum speed: | 2.5m/s,Related to resolution and counter minimum clock frequency |
| Reference origin (optional): | Magnetic sensor on the side of the readhead |
| Reference origin unidirectional repeatability: | 1LSB (≤20mm/s) |
| Reference origin unidirectional repeatability: | 1.5 microns in one direction |
Scale specification
| Dimensions: | W 6mm × H 0.1mm |
| Adhesive thickness: | W 5mm × H 0.1mm |
| Grid pitch: | 40μm |
| Accuracy grade: | ±10μm (L4 scale) |
Cable parameters
| Cable outer diameter: | 3.4mm±0.2mm |
| Bending times: | 20 million times, the bending radius is greater than 25mm |
Environmental parameters
| Storage temperature: | -20°C to 70°C |
| Operating temperature: | 0°C to 70°C |
| Vibration level: | 55Hz to 2000Hz max. 100m/s2 3 axes |
| Protection class: | IP40 |
Reading head installation size
Recommended thread engagement length minimum 5, tightening torque 0.25 to 0.4Nm
*All above dimensions are in millimeters
SE40 Reading head installation precautions
1. Scale placement tools must be used for scale placement, and freehand placement is prohibited.
2. Because there may be mounting stress, it takes 24 hours after the scale is mounted before the accuracy calibration can be performed, and it takes longer when the temperature is low.
3. For the long-term reliability of the application, the main body of the application (linear motor, machine) needs to be reliably grounded and shielded to prevent the reading head from being disturbed, and the power line and signal line should be kept as close as possible.Volume separation arrangement.
4. The power supply terminal of the reading head needs to meet 5V±10%, and the current is not less than 300mA.
5. Dirt on the scale may lead to increased output signal noise or position failure. Therefore, the scale must be kept clean. The scale can be cleaned with dust-free paper and ethanol or isopropanol.
6. The fixing screw of the reading head must be in accordance with the length and torque given in the installation diagram, otherwise the reading head may be damaged or poorly fixed.
Installation of grid ruler
Interface wire sequence
D-SUB 15 plug R wire sequence
| Pin number | Function | Pin number | Function |
| Pin1 | / | Pin9 | 0V is internally connected to Pin2 |
| Pin2 | 0V | Pin10 | / |
| Pin3 | / | Pin11 | / |
| Pin4 | Differential TTL Z- | Pin12 | Differential TTL Z+ |
| Pin5 | Differential TTL B- | Pin13 | Differential TTL B+ |
| Pin6 | Differential TTL A- | Pin14 | Differential TTL A+ |
| Pin7 | +5V±10% | Pin15 | / |
| Pin8 | +5V is internally connected to Pin7 | shell | outer shield |
D-SUB 9 plug M line sequence
| Pin number | Function | Pin number | Function |
| Pin1 | 0V | Pin6 | Differential TTL A- |
| Pin2 | Differential TTL A+ | Pin7 | Differential TTL Z- |
| Pin3 | Differential TTL Z+ | Pin8 | Differential TTL B- |
| Pin4 | Differential TTL B+ | Pin9 | / |
| Pin5 | +5V±10% | shell | outer shield |
D-SUB 9 plug T wire sequence
| Pin number | Function | Pin number | Function |
| Pin1 | Differential TTL A- | Pin6 | Differential TTL A+ |
| Pin2 | 0V | Pin7 | +5V±10% |
| Pin3 | Differential TTL B- | Pin8 | Differential TTL B+ |
| Pin4 | / | Pin9 | Differential TTL Z+ |
| Pin5 | Differential TTL Z- | shell | outer shield |
Readhead differential TLL electrical connections
Readhead indicator light
Readhead indicator lights indicate signal strength
| solid red light | The signal strength is less than 30%, the reading head is not working properly, the scale needs to be cleaned or the position of the reading head should be adjusted |
| solid yellow light | Signal strength <50%, the reading head can work normally, need to clean the scale or adjust the position of the reading head |
| solid green light | Signal strength < 80%, the reading head can work normally |
| solid blue light | Signal strength ≥ 80%, the reading head can work normally |
Repair and Maintenance
| Item | Specifications | Remarks |
|---|---|---|
| Update Date | Dongguan NEVA Precision Instument Co., Ltd. | 2025 |
| Lead time | within 30 days | Can be expedited |
| Material | See product manual | Request Inspection Report |
| Application | Applicable to multiple industries | Complies with standards |
| Keywords | ||
Clients Reviews