The beam detector has four adjustable operational range of between 8 to 20, 40, 70 and 100 meters beside
with three adjustable sensitivity setting ranges from 2.6dB to 4.8dB to meet the specific environmental
requirement. The detector works on the principle of reflective infrared beam obscuration. Used in conjunction
Specifications
Part Number
Standard
Compliance EN54-12
Fire Detection and Alarm Systems BS 5839 Part 1:2002
Specification
Operating Voltage 20 V to 28 V DC
Current Parameters Standby:23mA Commission:40μA Alarm:33mA
Beam Sensor Sensitivity [via Encoder] Level 1: 2.6 dB High Sensitivity
Level 2: 3.4 Medium Sensitivity
Level 3: 4.8 dB Low Sensitivity
Beam Pathway Length [via Encoder] Span 1: 8 to 20 meters Short Path
Span 2: 20 to 40 meters Short Path
Span 3: 40 to 70 meters Normal Path
Span 4: 70 to 100 meters Long Path
Beam Path Angle ±0.5o Directional
Alignment Guide Laser Beam Pointer
Digital Display Guide Nixie Tube
LED Indicator Guide Red: Fire ; Yellow: Fault ; Green: Alignment
Reset Time Less than 2 Second
Relay Capacity [Fire & Fault] Normally Open/ 2.0 A; 30 VDC
Physical
Material / Colour ABS / White
Dimension / Weight L:190.87 x W:126.87 x H:91.96 mm / 440 gm
Weight 0.130 Kg with base
Environmental
Operating Temperature / Protection Rating -10°C to 55°C / IP30 [IP66 glue seal]
Humidity 0 to 95% Relative Humidity, Non condensing
| Item | Specifications | Remarks |
|---|---|---|
| Update Date | Shenzhen Zoanco Electronics Co.,Ltd. | 2026 |
| Lead time | within 30 days | Can be expedited |
| Material | See product manual | Request Inspection Report |
| Application | Applicable to multiple industries | Complies with standards |
| Keywords | Conventional,Reflective,Optical,Detector,Output,Spaces | |
Tanda optical beam detectors suit large open spaces like warehouses; align reflector precisely and clean lenses quarterly to prevent false negatives. Integrate relay output with central FACP for coordinated alarm response. (for reference only)
Clients Reviews
PennyPincher
2026-04-07Exactly the aesthetic I was searching for!
Hunter
2026-04-07Is it RoHS or CE certified?
Regtiso Network Tech
2026-04-07Can multiple units be used together?
Wabi-Sabi
2026-04-07Can I apply a promotional code after placing an order?